Test Code MGB Mammaglobin (MGB) Immunostain, Technical Component Only


Shipping Instructions


Attach the green pathology address label and the pink Immunostain Technical Only label included in the kit to the outside of the transport container.



Specimen Required


Supplies: Immunostain Technical Only Envelope (T693)

Specimen Type: Tissue

Container/Tube: Immunostains Technical Only Envelope (T693)

Preferred: 2 unstained positively charged glass slide (25 x 75 x 1mm) per test ordered; sections 4-microns thick.

Acceptable: Formalin-fixed, paraffin-embedded (FFPE) tissue block

Additional Information:

1. Information on accessing digital images of IHC stains and the manual requisition form can be accessed through this website: www.mayomedicallaboratories.com/test-info/ihc/index.html

2. Clients ordering stains using a manual requisition form will not have access to digital images.

3. Clients wishing to access digital images must place the order for IHC stains electronically. Information regarding digital imaging can be accessed through this website: www.mayomedicallaboratories.com/test-info/ihc/faq.html


Secondary ID

70507

Useful For

Breast-specific marker

 

Aids in evaluating tumors of unknown primary site

Disease States

  • Breast cancer

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
IHTOI IHC Initial, Tech Only No No
IHTOA IHC Additional, Tech Only No No

Method Name

Immunohistochemistry

Reporting Name

Mammaglobin IHC, Tech Only

Specimen Type

TECHONLY

Specimen Stability Information

Specimen Type Temperature Time
TECHONLY Ambient (preferred)
  Refrigerated 

Reject Due To

Hemolysis

NA

Lipemia

NA

Icterus

NA

Other

Wet/frozen tissue
Cytology smears
Non-formalin fixed tissue
Non-paraffin embedded tissue
Non-charged slides
ProbeOn slides

Clinical Information

Mammaglobin, a mammary specific member of the uteroglobin family, is known to be overexpressed in human breast cancer. It may be valuable when used in a panel with GCDFP-15 and ER to evaluate tumors of unknown primary site.

Interpretation

This test includes only technical performance of the stain (no pathologist interpretation is performed). If diagnostic consultation by a pathologist is required order PATHC / Pathology Consultation.

 

The positive and negative controls are verified as showing appropriate immunoreactivity. If a control tissue is not included on the slide, a scanned image of the relevant quality control tissue is available upon request. Contact 855-516-8404.

Clinical Reference

1. Bernstein JL, Godbold JH, Raptis G, et al: Identification of mammaglobin as a novel serum marker for breast cancer. Clin Cancer Res 2005 Sep 15;11(18):6528-35

2. Leygue E, Snell L, Dotzlaw H, et al: Mammaglobin, a potential marker of breast cancer nodal metastasis. J Pathol 1999 Sep;189(1):28-33

Day(s) and Time(s) Performed

Monday through Friday

Analytic Time

1 day

Performing Laboratory

Mayo Medical Laboratories in Rochester

Test Classification

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

88342-TC, primary

88341-TC, if additional IHC

LOINC Code Information

Result ID Test Result Name Result LOINC Value
70819 Mammaglobin IHC, Tech Only No LOINC Needed